Christmas sale: 20% off products with code XMAS20
Australian Owned & OperatedLaboratory research use only. Not for human or animal use.

Documentation Guide

How to read a certificate of analysis for a research peptide

A certificate of analysis is the document that answers “what is in this vial, and how do you know?” For a research peptide it usually reports two things: how much of the sample is the peptide, and whether the peptide is the one the label claims. This guide walks through each field so the report can be read on its own terms.

First: who issued it, and for which batch

The most important line on any COA is the name of the laboratory that produced it. A report written by the supplier of a product is not the same document as a report written by an independent laboratory that was sent a sample. The reports published in our COA library were produced by Janoshik Analytical, an independent laboratory that tests by high-performance liquid chromatography (HPLC) and mass spectrometry. Each entry on that page is labelled with its source, so you can see which body produced the document.

Next, match the batch. A certificate applies to one specific batch, and the batch number on the report should match the batch number associated with the product you are holding. A report for a different batch, or for a different strength, does not describe your item even if it is for the same compound. On a product page, the COA link is specific to the strength being viewed for exactly this reason.

HPLC: the purity figure

HPLC separates a dissolved sample by passing it through a column, then measures what comes out. The result is a chromatogram: a line with peaks, where each peak is a component of the sample and the height or area under a peak reflects how much of it there is. Purity is reported as the percentage of the total signal represented by the main peak - the peptide's own peak.

A few things worth checking around that number. The method column should state the wavelength and the column used, because purity is only meaningful for a stated method. The retention time tells you when the main peak came out, which is how you match it between runs. And the purity figure itself is a percentage of the detected signal: it describes what the detector saw, not an absolute guarantee that nothing undetected is present.

Mass spectrometry: is it the right molecule

Purity does not prove identity. A sample that is 99% pure could be 99% pure something else. Mass spectrometry answers the identity question by measuring the mass of the molecules in the sample. The reported molecular weight is compared with the mass the compound should have, calculated from its molecular formula.

On a report you will usually see the measured mass and, where relevant, its ion forms such as [M+H]+ or [M+2H]2+. Peptides fragment and ionise in predictable ways, so an experienced reader compares the whole pattern, not just one figure. The practical point for most readers is simpler: the measured mass should agree with the expected mass for the named compound.

The other fields on the page

  • Sample description and amount. What was sent and recorded. A sample recorded as slightly heavier than the nominal strength is normal: a vial is filled with an excess to account for losses, and the report states what was actually weighed.
  • Task or report number. The laboratory's own reference for the job, which is what a verification lookup uses.
  • Verification key. A short key printed at the foot of the report. It is what lets you check a copy against the laboratory's own record.
  • Appearance. Often a simple statement - a white powder, for example - describing what was received.
  • Date. When the analysis was carried out, distinct from when the batch was made.

Checking the report against the laboratory's record

A PDF can be edited. The way to be sure a report is genuine is to look it up at the source. Janoshik Analytical publishes a verification page where a report can be found from the key printed on it, and each entry in our library carries the key that goes with it. Open the Janoshik verification page and enter the key. What comes back should match the document you started with, including the compound and the purity result.

What a COA does not say

A certificate of analysis is a record of what one laboratory measured in one sample on one date. It is not a licence, an approval, or a statement of suitability for any particular use. Sterility, endotoxin content and residual solvents, for example, are separate tests and are only reported where the report says so. For a research material the COA's job is to confirm identity and purity, and it is best read as exactly that.

Where no certificate has been published for a given strength, our product pages say so rather than substituting a report for a different batch. The Testing & Quality page explains how each document is matched to the batch it describes, and request documentation is the path when the document you need is not yet available.

Products in this guide

Solution calculator COA library Storage guide

Continue reading

For research use only. This guide describes published research and supply practice; it is not guidance on how to use any product.